Floorguard 1000 SL three-pack self-leveling topcoat

Floorguard 1000 SL is a heavy duty floor coating for concrete, base on non-solvent epoxy resin with smooth and self leveling property. Used for protecting and sealing new or existing concrete floors, easy washed and cleaned, no dust, impact resistance, chemical resistance and have Microban to protect surface from bacterial.

View DetailCompact

Intended use:

As a topcoat for concrete floor in chemical plants, warehouse, factory, cagewash areas, chemical processing plants, warehouse, factory, food and beverage plants.

Specifications

  • Type: Epoxy / Polyamide Solvent Free finish topcoat
  • Color: White and others
  • Film appearance: Gloss
  • Solid by volume: 100%
  • Flash point: 30°C
  • Wet film thickness: 1000 - 2000 microns
  • Dry film thickness: 1000 - 2000 microns
  • Practical coverage: 0.45 - 0.9 m²/litre or 1.7 - 3.4 m²/Gallon
  • Drying time:
  • - Temperature: 25°C - 30°C - 35°C
  • - Surface dry: 4 hours - 3 hours - 2 hours
  • - Hard dry: 18 hours - 16 hours - 12 hours
  • Recoat dry:
  • - Temperature: 25°C - 30°C - 35°C
  • - Minimum: 18 hours - 16 hours - 12 hours
  • - Maximum: 5 days - 5 days - 5 days
  • Pot life:
  • - Temperature: 25°C - 30°C - 35°C
  • - Pot life: 45 mins - 30 mins - 20 mins

Construction methods

  • Application method: Brush, Roller, Trowel
  • Diluted by: No Diluted
  • Mixing Ratio: Part A - Part B - Part C
  • - By Volume: 2 - 1 - 0.8
  • - By Weight: 2 - 1 - 1.5 Mix Part A, Part B and Part C, strictly follow mix ratio recommendations and stir for 2-3 mins until the mixture is homogeneous after leave 5 minutes before application. TOA Thinner #31 for cleaning only

Construction Guide

* Surface Preparation:
- For New concrete - The concrete prior to laying plastic sheets to block moisture from underground.
Then it should be left for curing concrete to solid and dry for about 3-4 weeks. Then, clean the surface free from dust, dirt, grease and most importantly, the surface is completely dry. (Check moisture content must be less than 10%)
- For Old concrete - To remove the old paint film which loosely adhesion to as much as possible by Scraping with a shovel or Grinding machine to enhance adhesion. Then, clean the surface free from grease and oil with suitable solvent. Before primer coating should clean all surfaces free from dust, dirt, grease and most importantly, the surface is completely dry. (Check moisture content must be less than 10%).
- For Floor Hardener or Surface glossy finish :
+ Concrete surface preparation by using dust free captive blasting units, grinding equipment, sand blasting for increase adhesion of coating.
+ Inspect the concrete for bug holes void, fin and other imperfections. Protrusions shall be ground smooth while voids shall be filled with Floorguard Putty or other suitable filler and polishing of surface with moltoprene disk.
+ After cleaning, repair surface defects and remove detericrated previous coatings. (Check moisture content must be less than 10%).
* Before Recoat by Topcoat:
- Remover all oil, grease, dirt, oxide and other foreign material by cleaning per SSPC-SP1, Solvent Cleaning before coating.
- If over 7 days gives cleaning surface by sand paper no. 320-400 and cleaning surface per SSPC-SP1, Solvent Cleaning before coating.

Recommended paint system

Protective coating:
- Primer
: 50 microns x 1 coat of Floorguard Primer


- Topcoat: 1000 microns x 1 coat of Floorguard 1000 SL